Our newly developed standoff foot gasketting technique has yielded measured results showing gasket height being held consistent to +/-0.0005" overall. Using our in-house scanning software package which can take 2D and 3D measurements, we have verified that these unprecedented results are now a production level reality. Material rheology and environmental factors will still contribute to the overall repeatability of gasket height, but this technique reduces the impact of mechanical positioning by an order of magnitude or better.
|